Mode (0x3) - (0x20505041)
  Mode
    Mode   APP  (0x20505041)

UID (0x5) - (0x37d1440f638c45fcbed6f45cfee5ca83)
  UID
    UID   0x37d1440f638c45fcbed6f45cfee5ca83 (0x37d1440f638c45fcbed6f45cfee5ca83)

Version (0xf) - (0xf7071005)
  Version
    Version   0xf7071005 (0xf7071005)

Command Register for CMD1 (0x8) - (0x0)
  Command Register for CMD1
    4cc Command    (0x0)

Data Register for CMD1 (0x9) - (0x0)
  Data Register for CMD1
    Word 1 (Least Significant)   0x0 (0x0)
    Word 2                       0x0 (0x0)
    Word 3                       0x0 (0x0)
    Word 4                       0x0 (0x0)
    Word 5                       0x0 (0x0)
    Word 6                       0x0 (0x0)
    Word 7                       0x0 (0x0)
    Word 8                       0x0 (0x0)
    Word 9                       0x0 (0x0)
    Word 10                      0x0 (0x0)
    Word 11                      0x0 (0x0)
    Word 12                      0x0 (0x0)
    Word 13                      0x0 (0x0)
    Word 14                      0x0 (0x0)
    Word 15                      0x0 (0x0)
    Word 16                      0x0 (0x0)

Command Register for CMD2 (0x10) - (0x0)
  Command Register for CMD2
    4cc Command    (0x0)

Data Register for CMD2 (0x11) - (0x0)
  Data Register for CMD2
    Word 1 (Least Significant)   0x0 (0x0)
    Word 2                       0x0 (0x0)
    Word 3                       0x0 (0x0)
    Word 4                       0x0 (0x0)
    Word 5                       0x0 (0x0)
    Word 6                       0x0 (0x0)
    Word 7                       0x0 (0x0)
    Word 8                       0x0 (0x0)
    Word 9                       0x0 (0x0)
    Word 10                      0x0 (0x0)
    Word 11                      0x0 (0x0)
    Word 12                      0x0 (0x0)
    Word 13                      0x0 (0x0)
    Word 14                      0x0 (0x0)
    Word 15                      0x0 (0x0)
    Word 16                      0x0 (0x0)

Interrupt Event for I2C1 (0x14) - (0x2000008)
  Interrupt Event for I2C1
    Interrupt Event for I2C1
      Soft Reset                                    False (0x0)
      Hard Reset                                    False (0x0)
      Cable Reset Event                             False (0x0)
      Plug Insert or Removal                        True (0x1)
      PR Swap Complete                              False (0x0)
      DR Swap Complete                              False (0x0)
      FR Swap Complete                              False (0x0)
      RDO Received from Sink                        False (0x0)
      Built-In Self Test                            False (0x0)
      Overcurrent Event                             False (0x0)
      Attention Received                            False (0x0)
      Vendor-Defined Message Received               False (0x0)
      New Contract as Consumer                      False (0x0)
      New Contract as Provider                      False (0x0)
      Source Capabilities Message Ready             False (0x0)
      Sink Capabilities Message Ready               False (0x0)
      Low Voltage Warning                           False (0x0)
      PR Swap Requested                             False (0x0)
      DR Swap Requested                             False (0x0)
      Goto Min Received                             False (0x0)
      USB Host Present                              False (0x0)
      USB Host Present no longer                    False (0x0)
      High Voltage Warning                          False (0x0)
      PP Switch Changed                             False (0x0)
      Power Status Update                           False (0x0)
      Data Status Update                            True (0x1)
      Status Update                                 False (0x0)
      PD Status Update                              False (0x0)
      VCONN Swap Complete                           False (0x0)
      VCONN Swap Requested                          False (0x0)
      CMD1 Complete                                 False (0x0)
      CMD2 Complete                                 False (0x0)
      Error: Device Incompatible                    False (0x0)
      Error: Cannot Provide Voltage or Current      False (0x0)
      Error: Can Provide Voltage or Current Later   False (0x0)
      Error: Power Event Occurred                   False (0x0)
      Error: Missing Get Capabilities Message       False (0x0)
      Error: Protocol Error                         False (0x0)
      Error: Message Data                           False (0x0)
      Error: Discharge Failed                       False (0x0)
      Sink Transition Complete                      False (0x0)
      Error: Unable to Source                       False (0x0)
      Error: BIST Message Ignored                   False (0x0)
      AM Entry Failure                              False (0x0)
      AM Entered                                    False (0x0)
      Vendor Defined Message Sent                   False (0x0)
      Discover Mode Complete                        False (0x0)
      Exit Mode Complete                            False (0x0)
      User SVID Mode Entered                        False (0x0)
      User SVID Mode Exited                         False (0x0)
      User SVID Attention VDM Received              False (0x0)
      User SVID Other VDM Received                  False (0x0)
      DP SID Status Update                          False (0x0)
      Intel VID Status Update                       False (0x0)
      PD3 Status Update                             False (0x0)
      TX Mem Buffer Empty                           False (0x0)
      RX Mem Buffer Full                            False (0x0)
      Custom VDM Arrive                             False (0x0)
      Custom AM Entered                             False (0x0)
      Custom VDM Message Sent                       False (0x0)
      SOC ACK Timeout                               False (0x0)
      FRS Signal Received                           False (0x0)
      Chunk Response Received                       False (0x0)
      Chunk Request Received                        False (0x0)
      Alert Message Received                        False (0x0)
    Common Interrupt Mask for I2C1
      Patch Loaded      False (0x0)
      Ready for Patch   False (0x0)

Interrupt Event for I2C2 (0x15) - (0x2000008)
  Interrupt Event for I2C2
    Interrupt Event for I2C2
      Soft Reset                                    False (0x0)
      Hard Reset                                    False (0x0)
      Cable Reset Event                             False (0x0)
      Plug Insert or Removal                        True (0x1)
      PR Swap Complete                              False (0x0)
      DR Swap Complete                              False (0x0)
      FR Swap Complete                              False (0x0)
      RDO Received from Sink                        False (0x0)
      Built-In Self Test                            False (0x0)
      Overcurrent Event                             False (0x0)
      Attention Received                            False (0x0)
      Vendor-Defined Message Received               False (0x0)
      New Contract as Consumer                      False (0x0)
      New Contract as Provider                      False (0x0)
      Source Capabilities Message Ready             False (0x0)
      Sink Capabilities Message Ready               False (0x0)
      Low Voltage Warning                           False (0x0)
      PR Swap Requested                             False (0x0)
      DR Swap Requested                             False (0x0)
      Goto Min Received                             False (0x0)
      USB Host Present                              False (0x0)
      USB Host Present no longer                    False (0x0)
      High Voltage Warning                          False (0x0)
      PP Switch Changed                             False (0x0)
      Power Status Update                           False (0x0)
      Data Status Update                            True (0x1)
      Status Update                                 False (0x0)
      PD Status Update                              False (0x0)
      VCONN Swap Complete                           False (0x0)
      VCONN Swap Requested                          False (0x0)
      CMD1 Complete                                 False (0x0)
      CMD2 Complete                                 False (0x0)
      Error: Device Incompatible                    False (0x0)
      Error: Cannot Provide Voltage or Current      False (0x0)
      Error: Can Provide Voltage or Current Later   False (0x0)
      Error: Power Event Occurred                   False (0x0)
      Error: Missing Get Capabilities Message       False (0x0)
      Error: Protocol Error                         False (0x0)
      Error: Message Data                           False (0x0)
      Error: Discharge Failed                       False (0x0)
      Sink Transition Complete                      False (0x0)
      Error: Unable to Source                       False (0x0)
      Error: BIST Message Ignored                   False (0x0)
      AM Entry Failure                              False (0x0)
      AM Entered                                    False (0x0)
      Vendor Defined Message Sent                   False (0x0)
      Discover Mode Complete                        False (0x0)
      Exit Mode Complete                            False (0x0)
      User SVID Mode Entered                        False (0x0)
      User SVID Mode Exited                         False (0x0)
      User SVID Attention VDM Received              False (0x0)
      User SVID Other VDM Received                  False (0x0)
      DP SID Status Update                          False (0x0)
      Intel VID Status Update                       False (0x0)
      PD3 Status Update                             False (0x0)
      TX Mem Buffer Empty                           False (0x0)
      RX Mem Buffer Full                            False (0x0)
      Custom VDM Arrive                             False (0x0)
      Custom AM Entered                             False (0x0)
      Custom VDM Message Sent                       False (0x0)
      SOC ACK Timeout                               False (0x0)
      FRS Signal Received                           False (0x0)
      Chunk Response Received                       False (0x0)
      Chunk Request Received                        False (0x0)
      Alert Message Received                        False (0x0)
    Common Interrupt Mask for I2C1
      Patch Loaded      False (0x0)
      Ready for Patch   False (0x0)

Interrupt Clear for I2C1 (0x18) - (0x2000008)
  Interrupt Event for I2C1
    Interrupt Event for I2C1
      Soft Reset                                    False (0x0)
      Hard Reset                                    False (0x0)
      Cable Reset Event                             False (0x0)
      Plug Insert or Removal                        True (0x1)
      PR Swap Complete                              False (0x0)
      DR Swap Complete                              False (0x0)
      FR Swap Complete                              False (0x0)
      RDO Received from Sink                        False (0x0)
      Built-In Self Test                            False (0x0)
      Overcurrent Event                             False (0x0)
      Attention Received                            False (0x0)
      Vendor-Defined Message Received               False (0x0)
      New Contract as Consumer                      False (0x0)
      New Contract as Provider                      False (0x0)
      Source Capabilities Message Ready             False (0x0)
      Sink Capabilities Message Ready               False (0x0)
      Low Voltage Warning                           False (0x0)
      PR Swap Requested                             False (0x0)
      DR Swap Requested                             False (0x0)
      Goto Min Received                             False (0x0)
      USB Host Present                              False (0x0)
      USB Host Present no longer                    False (0x0)
      High Voltage Warning                          False (0x0)
      PP Switch Changed                             False (0x0)
      Power Status Update                           False (0x0)
      Data Status Update                            True (0x1)
      Status Update                                 False (0x0)
      PD Status Update                              False (0x0)
      VCONN Swap Complete                           False (0x0)
      VCONN Swap Requested                          False (0x0)
      CMD1 Complete                                 False (0x0)
      CMD2 Complete                                 False (0x0)
      Error: Device Incompatible                    False (0x0)
      Error: Cannot Provide Voltage or Current      False (0x0)
      Error: Can Provide Voltage or Current Later   False (0x0)
      Error: Power Event Occurred                   False (0x0)
      Error: Missing Get Capabilities Message       False (0x0)
      Error: Protocol Error                         False (0x0)
      Error: Message Data                           False (0x0)
      Error: Discharge Failed                       False (0x0)
      Sink Transition Complete                      False (0x0)
      Error: Unable to Source                       False (0x0)
      Error: BIST Message Ignored                   False (0x0)
      AM Entry Failure                              False (0x0)
      AM Entered                                    False (0x0)
      Vendor Defined Message Sent                   False (0x0)
      Discover Mode Complete                        False (0x0)
      Exit Mode Complete                            False (0x0)
      User SVID Mode Entered                        False (0x0)
      User SVID Mode Exited                         False (0x0)
      User SVID Attention VDM Received              False (0x0)
      User SVID Other VDM Received                  False (0x0)
      DP SID Status Update                          False (0x0)
      Intel VID Status Update                       False (0x0)
      PD3 Status Update                             False (0x0)
      TX Mem Buffer Empty                           False (0x0)
      RX Mem Buffer Full                            False (0x0)
      Custom VDM Arrive                             False (0x0)
      Custom AM Entered                             False (0x0)
      Custom VDM Message Sent                       False (0x0)
      SOC ACK Timeout                               False (0x0)
      FRS Signal Received                           False (0x0)
      Chunk Response Received                       False (0x0)
      Chunk Request Received                        False (0x0)
      Alert Message Received                        False (0x0)
    Common Interrupt Mask for I2C1
      Patch Loaded      False (0x0)
      Ready for Patch   False (0x0)

Interrupt Clear for I2C2 (0x19) - (0x2000008)
  Interrupt Event for I2C2
    Interrupt Event for I2C2
      Soft Reset                                    False (0x0)
      Hard Reset                                    False (0x0)
      Cable Reset Event                             False (0x0)
      Plug Insert or Removal                        True (0x1)
      PR Swap Complete                              False (0x0)
      DR Swap Complete                              False (0x0)
      FR Swap Complete                              False (0x0)
      RDO Received from Sink                        False (0x0)
      Built-In Self Test                            False (0x0)
      Overcurrent Event                             False (0x0)
      Attention Received                            False (0x0)
      Vendor-Defined Message Received               False (0x0)
      New Contract as Consumer                      False (0x0)
      New Contract as Provider                      False (0x0)
      Source Capabilities Message Ready             False (0x0)
      Sink Capabilities Message Ready               False (0x0)
      Low Voltage Warning                           False (0x0)
      PR Swap Requested                             False (0x0)
      DR Swap Requested                             False (0x0)
      Goto Min Received                             False (0x0)
      USB Host Present                              False (0x0)
      USB Host Present no longer                    False (0x0)
      High Voltage Warning                          False (0x0)
      PP Switch Changed                             False (0x0)
      Power Status Update                           False (0x0)
      Data Status Update                            True (0x1)
      Status Update                                 False (0x0)
      PD Status Update                              False (0x0)
      VCONN Swap Complete                           False (0x0)
      VCONN Swap Requested                          False (0x0)
      CMD1 Complete                                 False (0x0)
      CMD2 Complete                                 False (0x0)
      Error: Device Incompatible                    False (0x0)
      Error: Cannot Provide Voltage or Current      False (0x0)
      Error: Can Provide Voltage or Current Later   False (0x0)
      Error: Power Event Occurred                   False (0x0)
      Error: Missing Get Capabilities Message       False (0x0)
      Error: Protocol Error                         False (0x0)
      Error: Message Data                           False (0x0)
      Error: Discharge Failed                       False (0x0)
      Sink Transition Complete                      False (0x0)
      Error: Unable to Source                       False (0x0)
      Error: BIST Message Ignored                   False (0x0)
      AM Entry Failure                              False (0x0)
      AM Entered                                    False (0x0)
      Vendor Defined Message Sent                   False (0x0)
      Discover Mode Complete                        False (0x0)
      Exit Mode Complete                            False (0x0)
      User SVID Mode Entered                        False (0x0)
      User SVID Mode Exited                         False (0x0)
      User SVID Attention VDM Received              False (0x0)
      User SVID Other VDM Received                  False (0x0)
      DP SID Status Update                          False (0x0)
      Intel VID Status Update                       False (0x0)
      PD3 Status Update                             False (0x0)
      TX Mem Buffer Empty                           False (0x0)
      RX Mem Buffer Full                            False (0x0)
      Custom VDM Arrive                             False (0x0)
      Custom AM Entered                             False (0x0)
      Custom VDM Message Sent                       False (0x0)
      SOC ACK Timeout                               False (0x0)
      FRS Signal Received                           False (0x0)
      Chunk Response Received                       False (0x0)
      Chunk Request Received                        False (0x0)
      Alert Message Received                        False (0x0)
    Common Interrupt Mask for I2C1
      Patch Loaded      False (0x0)
      Ready for Patch   False (0x0)

Status (0x1a) - (0x10020003f)
  Status
    Plug Present               Plug present, see Conn State (below) for details. (0x1)
    Conn State                 Connection present, Ra detected (Rd and Ra detected) or Rp detected with previous Ra detection (assumes PD Controller started as Source and later swapped to Sink). (0x7)
    Plug Orientation           Upside-down orientation (plug CC on C_CC2). (0x1)
    Port Role                  PD Controller is Source (C_CCx pull-up active). (0x1)
    Data Role                  PD Controller is UFP or port is disabled/disconnected. (0x0)
    VBUS Status                VBUS is at other PD-negotiated power level and within expected limits. See ADC Results for exact voltage provided multi-channel ADC is active. (0x2)
    USB Host Present           No far-end device present providing VBUS or PD Controller power role is Source. (0x0)
    Acting as Legacy           PD Controller is not in a legacy (non PD mode). (0x0)
    Go To Min Active           No PD contract established or GotoMin restriction has been cleared by Source Capabilities message or disconnect/Hard Reset. (0x0)
    BIST                       No BIST in progress (0x0)
    High Voltage Warning       PD Controller operating as Sink or VBUS voltage is below limit specified by HighVoltageWarningLimit register or port is disconnected. (0x0)
    Low Voltage Warning        PD Controller operating as Sink or VBUS voltage is above limit specified by LowVoltageWarningLimit register or port is disconnected. (0x0)
    SOC ACK Timeout Occurred   Unknown (0x0) (0x0)
    Alternative Mode Status    At least one Alternate Mode entry successful. (0x1)

Power Path Status (0x26) - (0x4001000402)
  Power Path Status
    PP1_Cableswitch         PP1_CABLE switch CC1 enabled (system output). (0x2)
    PP2_Cableswitch         PP2_CABLE switch disabled. (0x0)
    PP1switch               PP1 switch disabled. (0x0)
    PP2switch               PP2 switch enabled (system output). (0x2)
    PP3switch               PP3 switch disabled. (0x0)
    PP4switch               PP4 switch disabled. (0x0)
    PP1_CABLE Enable        PP1_CABLE power enabled (0x1)
    PP2_CABLE Enable        PP2_CABLE power not enabled (0x0)
    PP1 Overcurrent         No overcurrent condition exists on PP1 switch (0x0)
    PP2 Overcurrent         No overcurrent condition exists on PP2 switch (0x0)
    PP1_CABLE Overcurrent   No overcurrent condition exists on PP1_CABLE switch (0x0)
    PP2_CABLE Overcurrent   No overcurrent condition exists on PP2_CABLE switch (0x0)
    PowerSource             PD Controller is powered from VIN_3P3. (0x1)
    PP1_RCP                 0x0 (0x0)
    PP2_RCP                 0x0 (0x0)

Boot Flags (0x2d) - (0x30000006a200000018)
  Boot Flags
    Patch Header Error                 False (0x0)
    Dead Battery Flag                  False (0x0)
    SPI Flash Present                  True (0x1)
    Region 0                           True (0x1)
    Region 1                           False (0x0)
    Region 0 Invalid                   False (0x0)
    Region 1 Invalid                   False (0x0)
    Region 0 Flash Error               False (0x0)
    Region 1 Flash Error               False (0x0)
    Patch Download Error               False (0x0)
    Region 0 CRC Fail                  False (0x0)
    Region 1 CRC Fail                  False (0x0)
    Customer OTP Invalid               False (0x0)
    PP1 Switch                         False (0x0)
    PP2 Switch                         False (0x0)
    PP3 Switch                         False (0x0)
    PP4 Switch                         False (0x0)
    Customer OTP Valid                 Unknown (0x2) (0x2)
    OTP Customer Dead Battery          Bus Power From ADCIN (0x0)
    OTP I2C Address [6:5] for I2C2     0x2 (0x2)
    OTP Customer TBT Present           False (0x0)
    OTP Customer I2C Threshold         True (0x1)
    OTP Customer TBT Controller Type   0x2 (0x2)
    OTP Customer Disable PD            True (0x1)
    Revision ID Metal                  0x0 (0x0)
    Revision ID Base                   TPS65988 (0x4)

Build Identifier (0x2e) - (0x38313032323131305f65363464626661346134303835363361626635336163373466366638383239386230303138353736)
  Build Identifier
    Build Identifier   0x38313032323131305f65363464626661346134303835363361626635336163373466366638383239386230303138353736 (0x38313032323131305f65363464626661346134303835363361626635336163373466366638383239386230303138353736)

Device Info (0x2f) - (0xf7071000324543410000000000316563415a2030302e30312e37303746574620303330305748203838393536535054)
  Device Info
    Device Info   TPS65988 HW0030 FWF707.10.00 ZAce1     ACE2  (0xf7071000324543410000000000316563415a2030302e30312e37303746574620303330305748203838393536535054)

Received Source Capabilities (0x30) - (0x1900000)
  Received Source Capabilities
    Number of Source PDOs   0 (0x0)

Received Sink Capabilities (0x31) - (0x1900000)
  Received Sink Capabilities
    Number of Sink PDOs   0 (0x0)

Active Contract PDO (0x34) - (0x1912c)
  Active Contract PDO
    Maximum Current   3 A (0x12c)
    Voltage           5 V (0x64)
    Peak Current      100% (0x0)
    reserved          reserved, set 0 (0x0)
    Supply Type       Fixed Source (0x0)

Active Contract RDO (0x35) - (0x1304b12c)
  Active Contract RDO
    Max/Min Operating Current   3 A (0x12c)
    Operating Current           3 A (0x12c)
    No USB Suspend              True (0x1)
    USB Communication Capable   True (0x1)
    Capability Mismatch         False (0x0)
    Giveback Flag               False (0x0)
    Object Position             1 (0x1)

Sink Request RDO (0x36) - (0x1304b12c)
  Sink Request RDO
    Max/Min Operating Current   3 A (0x12c)
    Operating Current           3 A (0x12c)
    No USB Suspend              True (0x1)
    USB Communication Capable   True (0x1)
    Capability Mismatch         False (0x0)
    Giveback Flag               False (0x0)
    Object Position             1 (0x1)

Power Status (0x3f) - (0xd)
  Power Status
    Power Connection           Connection Present (0x1)
    Source or Sink             Source (0x0)
    Type-C Current             PD Contract Negotiated (0x3)
    Charger Detect Status      Disabled or Not Run (0x0)
    Charger Advertise Status   Disabled or Not Run (0x0)

PD Status (0x40) - (0x70)
  PD Status
    Plug Details         USB Type-C full-featured plug (0x0)
    CC Pull-up           Not in CC pull-down mode / no CC pull-up detected. (0x0)
    Port Type            Source/Sink (0x3)
    Present Role         Source (0x1)
    Soft Reset Details   Reset value, no soft reset (0x0)
    Hard Reset Details   Reset value, no hard reset. (0x0)

PD3.0 Status (0x41) - (0x30000000)
  PD3.0 Status
    PD3.0 Status
      Received Message not supported             0 (0x0)
      Source Capabilities Received Message       0 (0x0)
      Security Response Received Message         0 (0x0)
      Get Source Capabilities Received Message   0 (0x0)
      Security Request Message received          0 (0x0)
      Port Partner Negotiation SVDM received     PD Specification  revision 1 (0x0)
      Plug Partner Negotiation SVDM received     PD Specification  revision 1 (0x0)
      Port Partner Negotiation received          PD Specification  revision 1 (0x0)
      Plug Partner Negotiation received          PD Specification  revision 1 (0x0)
      Unchunked messages                         0 (0x0)

RX Identity SOP (0x48) - (0x0)
  RX Identity SOP
    VDO configuration
      Number of valid VDOs   0 (0x0)
      SOP Message Source     SOP Discover Identity request not sent or pending. (0x0)
    Received VDO
      UFP IDO Header
        USB Vendor ID                0x0 (0x0)
        Product Type (DFP)           Undefined (0x0)
        Modal Operation Supported    False (0x0)
        Product Type (UFP)           Undefined (0x0)
        Data Capable as USB Device   False (0x0)
        Data Capable as USB Host     False (0x0)
      Product Vendor Defined Object
        BCD Device       0x0 (0x0)
        USB Product ID   0x0 (0x0)
      Alternate Mode Adapter VDO
        USB SS Signalling       USB 2.0 Only (0x0)
        VBus Required           False (0x0)
        VConn Required          False (0x0)
        VConn Power             1 W (0x0)
        SSRx 2 Directionality   Fixed (0x0)
        SSRx 1 Directionality   Fixed (0x0)
        SSTx 2 Directionality   Fixed (0x0)
        SSTx 1 Directionality   Fixed (0x0)
        AMA Firmware Version    0x0 (0x0)
        AMA Hardware Version    0x0 (0x0)
      Certification Test ID   0x0 (0x0)
      UFP IDO VDO #5          0x0 (0x0)
      UFP IDO VDO #6          0x0 (0x0)

Received SOP Prime Identity Data Object (0x49) - (0x8205200000000000007a518001c2744)
  Received SOP Prime Identity Data Object
    Record Counts
      Number of Received Identity Objects   4 (0x4)
    Received SOP Prime Discover Identity Response
      SOP Prime IDO Header
        USB Vendor ID                0x0 (0x0)
        Product Type (DFP)           Undefined (0x0)
        Modal Operation Supported    False (0x0)
        Product Type (UFP)           Undefined (0x0)
        Data Capable as USB Device   False (0x0)
        Data Capable as USB Host     False (0x0)
      Product Vendor Defined Object
        BCD Device       0x0 (0x0)
        USB Product ID   0x0 (0x0)
      Cable Vendor Defined Object
        USB SS Signalling                  USB 2.0 Only (0x0)
        VBus Current Handling Capability   Reserved (0x0)
        Maximum Vbus Voltage               20V (0x0)
        Cable Termination Type             Both Ends Passive, VConn Not Required (0x0)
        Cable Latency                      reserved (0000b) (0x0)
        Type-C Plug to Type-C/Captive      reserved (0x0)
        VDO version                        0x0 (0x0)
        Cable Firmware Version             0x0 (0x0)
        Cable Hardware Version             0x0 (0x0)
      Certification Test ID   0x0 (0x0)
      SOP Prime IDO VDO #5    0x0 (0x0)
      SOP Prime IDO VDO #6    0x0 (0x0)

RX Attention structured VDM (0x4e) - (0x0)
  RX Attention structured Register
    RX Attention Status
      Number of Valid VDOs         0 (0x0)
      Number of Register Updates   0 (0x0)
    Data Objects Received
      Data Object 1
        Payload   0x0 (0x0)
        Type      Unstructured (0x0)
        SVID      0x0 (0x0)
      Data Object 2
        Data Object 2   0x0 (0x0)
      Data Object 3
        Data Object 3   0x0 (0x0)
      Data Object 4
        Data Object 4   0x0 (0x0)
      Data Object 5
        Data Object 5   0x0 (0x0)
      Data Object 6
        Data Object 6   0x0 (0x0)
      Data Object 7
        Data Object 7   0x0 (0x0)

RX VDM Register (0x4f) - (0x8205200000000000007a500000806ff018111e2)
  RX VDM Register
    RX VDM Status
      Number of Valid VDOs         2 (0x2)
      SOP Message Source           VDM came from SOP (0x0)
      Number of Register Updates   7 (0x7)
    Data Objects Received
      Data Object 1
        Command           Config (0x11)
        Command Type      Initiator (0x0)
        Object Position   1 (0x1)
        VDM Version       0 (0x0)
        Type              Structured (0x1)
        SVID              0xff01 (0xff01)
      Data Object 2
        Data Object 2   0x806 (0x806)
      Data Object 3
        Data Object 3   0x7a5 (0x7a5)
      Data Object 4
        Data Object 4   0x0 (0x0)
      Data Object 5
        Data Object 5   0x82052 (0x82052)
      Data Object 6
        Data Object 6   0x0 (0x0)
      Data Object 7
        Data Object 7   0x0 (0x0)

User VID Status Register (0x57) - (0x0)
  User VID Status
    User VID Status
      User VID Detected        False (0x0)
      User VID Active          False (0x0)
      User VID Error Code      0x0 (0x0)
      User VID Mode 1 Status   False (0x0)
      User VID Mode 2 Status   False (0x0)
      User VID Mode 3 Status   False (0x0)
      User VID Mode 4 Status   False (0x0)

DP SID Status (0x58) - (0xc0c4500000806000000010000001a03)
  DP SID Status
    DP Status TX
      Connection Status               UFP_D is connected (0x2)
      Power Low                       Adapter is functioning normally or disabled (0x0)
      Enabled                         DP functionality is enabled (0x1)
      Multi-function Preferred        Multi-function preferred (0x1)
      USB Configuration Request       Maintain current configuration (0x0)
      Exit DisplayPort Mode Request   Maintain current mode (0x0)
      HPD State                       HPD_Low (0x0)
      IRQ HPD                         No IRQ_HPD since last status (0x0)
      reserved                        reserved (0x0)
    DP Status RX
      Connection Status               DFP_D is connected (0x1)
      Power Low                       Adapter is functioning normally or disabled (0x0)
      Enabled                         DP functionality is Disabled (0x0)
      Multi-function Preferred        No Preference for Multi-function (0x0)
      USB Configuration Request       Maintain current configuration (0x0)
      Exit DisplayPort Mode Request   Maintain current mode (0x0)
      HPD State                       HPD_Low (0x0)
      IRQ HPD                         No IRQ_HPD since last status (0x0)
      reserved                        reserved (0x0)
    DP Configure
      Select Configuration                          Set configuration for UFP_U as UFP_D (0x2)
      Supports DP v1.3 signalling                   True (0x1)
      Supports USB Gen 2 signalling                 False (0x0)
      DFPD Receptacle or UFPD Plug Pin Assignment   D (0x8)
      UFPD Receptacle or DFPD Plug Pin Assignment   (none) (0x0)
      reserved                                      reserved (0x0)
    DP Mode Data
      Port Capability                               UFP_D capable (0x1)
      Supports DP v1.3 signalling                   True (0x1)
      Supports USB Gen 2 signalling                 False (0x0)
      DFPD Receptacle or UFPD Plug Pin Assignment   C, D (0xc)
      UFPD Receptacle or DFPD Plug Pin Assignment   C, D (0xc)
      reserved                                      reserved (0x0)
    DP Status To Plug
      Connection Status               Neither DFP_D or UFP_D connected (0x0)
      Power Low                       Adapter is functioning normally or disabled (0x0)
      Enabled                         DP functionality is Disabled (0x0)
      Multi-function Preferred        No Preference for Multi-function (0x0)
      USB Configuration Request       Maintain current configuration (0x0)
      Exit DisplayPort Mode Request   Maintain current mode (0x0)
      HPD State                       HPD_Low (0x0)
      IRQ HPD                         No IRQ_HPD since last status (0x0)
      reserved                        reserved (0x0)
    DP Status ACK From Plug
      Connection Status               Neither DFP_D or UFP_D connected (0x0)
      Power Low                       Adapter is functioning normally or disabled (0x0)
      Enabled                         DP functionality is Disabled (0x0)
      Multi-function Preferred        No Preference for Multi-function (0x0)
      USB Configuration Request       Maintain current configuration (0x0)
      Exit DisplayPort Mode Request   Maintain current mode (0x0)
      HPD State                       HPD_Low (0x0)
      IRQ HPD                         No IRQ_HPD since last status (0x0)
      reserved                        reserved (0x0)
    DP Configure to Plug
      Select Configuration                          Set configuration for USB (0x0)
      Supports DP v1.3 signalling                   False (0x0)
      Supports USB Gen 2 signalling                 False (0x0)
      DFPD Receptacle or UFPD Plug Pin Assignment   (none) (0x0)
      UFPD Receptacle or DFPD Plug Pin Assignment   (none) (0x0)
      reserved                                      reserved (0x0)
    DP Configure ACK From Plug
      Select Configuration                          Set configuration for USB (0x0)
      Supports DP v1.3 signalling                   False (0x0)
      Supports USB Gen 2 signalling                 False (0x0)
      DFPD Receptacle or UFPD Plug Pin Assignment   (none) (0x0)
      UFPD Receptacle or DFPD Plug Pin Assignment   (none) (0x0)
      reserved                                      reserved (0x0)
    DP Mode Data, SOP Prime
      Port Capability                               Reserved (0x0)
      Supports DP v1.3 signalling                   False (0x0)
      Supports USB Gen 2 signalling                 False (0x0)
      DFPD Receptacle or UFPD Plug Pin Assignment   (none) (0x0)
      UFPD Receptacle or DFPD Plug Pin Assignment   (none) (0x0)
      reserved                                      reserved (0x0)
    DP SID Detected   Far-end DFP_U has issued DP SID SVDM or UFP_U has responded with ACK (0x1)
    DP Mode Active    0x1 (0x1)
    Error Code        0x0 (0x0)

TI VID Status Register (0x5b) - (0x0)
  TI Mode Status
    Texas Instruments VID Status
      TI VID Status       False (0x0)
      TI PDIO Status      False (0x0)
      TI VID Error Code   0x0 (0x0)

RX User VID Attention VDM Register (0x60) - (0x0)
  RX User VID Attention VDM Register
    RX Attention Status
      Number of Valid VDOs         0 (0x0)
      Number of Register Updates   0 (0x0)
    Data Objects Received
      Data Object 1
        Payload   0x0 (0x0)
        Type      Unstructured (0x0)
        SVID      0x0 (0x0)
      Data Object 2
        Data Object 2   0x0 (0x0)
      Data Object 3
        Data Object 3   0x0 (0x0)
      Data Object 4
        Data Object 4   0x0 (0x0)
      Data Object 5
        Data Object 5   0x0 (0x0)
      Data Object 6
        Data Object 6   0x0 (0x0)
      Data Object 7
        Data Object 7   0x0 (0x0)

RX User VID Other VDM Register (0x61) - (0x0)
  RX User VID Other VDM Register
    RX VDM Status
      Number of Valid VDOs         0 (0x0)
      Number of Register Updates   0 (0x0)
    Data Objects Received
      Data Object 1
        Payload   0x0 (0x0)
        Type      Unstructured (0x0)
        SVID      0x0 (0x0)
      Data Object 2
        Data Object 2   0x0 (0x0)
      Data Object 3
        Data Object 3   0x0 (0x0)
      Data Object 4
        Data Object 4   0x0 (0x0)
      Data Object 5
        Data Object 5   0x0 (0x0)
      Data Object 6
        Data Object 6   0x0 (0x0)
      Data Object 7
        Data Object 7   0x0 (0x0)

Type C State Register (0x69) - (0x60020102)
  Type C State Register
    CC Pin For PD       C_CC2 is CC pin (0x2)
    CC1 Pin State       Ra detected (Source only) (0x1)
    CC2 Pin State       Rd detected (Source only) (0x2)
    Type C Port State   Attached SRC (0x60)

ADC results Register (0x6a) - (0x0)
  ADC results
    ADC conversion results
      Single ADC conversion      0 (0x0)
      Channel 1 ADC conversion   0 (0x0)
      Channel 2 ADC conversion   0 (0x0)
      Channel 3 ADC conversion   0 (0x0)
      Channel 4 ADC conversion   0 (0x0)

HW control Register (0x6b) - (0x0)
  HW control
    PWM enable
      Enable of PWM1      False (0x0)
      PWM1 clock source   100 kHz (0x0)
      PWM1 clock period   0 (0x0)
      PWM1 pulse width    0 (0x0)
    PWM 2
      Enable of PWM2       False (0x0)
      PWM2 clock source    100 kHz (0x0)
      PWM2 clock period    0 (0x0)
      PWM2 pulse width     0 (0x0)
    RCP mode
      PP1 Src RCP mode enable   Comparator Mode (0x0)
      PP1 Snk RCP mode enable   Ideal Diode Mode (0x0)
      PP2 Src RCP mode enable   Comparator Mode (0x0)
      PP2 Snk RCP mode enable   Ideal Diode Mode (0x0)

Received Manufacturer Info Data Block SOP (0x71) - (0x0)
  Received Manufacturer Info Data Block SOP
    VID                  0x0 (0x0)
    PID                  0x0 (0x0)
    ManufacturerString   0x0 (0x0)

GPIO Status Register (0x72) - (0x12c00700004007)
  GPIO Status Register
    GPIO0 Data         0x1 (0x1)
    GPIO1 Data         0x1 (0x1)
    GPIO2 Data         0x1 (0x1)
    GPIO3 Data         0x0 (0x0)
    GPIO4 Data         0x0 (0x0)
    GPIO5 Data         0x0 (0x0)
    GPIO6 Data         0x0 (0x0)
    GPIO7 Data         0x0 (0x0)
    GPIO8 Data         0x0 (0x0)
    GPIO9 Data         0x0 (0x0)
    GPIO10 Data        0x0 (0x0)
    GPIO11 Data        0x0 (0x0)
    GPIO12 Data        0x0 (0x0)
    GPIO13 Data        0x0 (0x0)
    GPIO14 Data        0x1 (0x1)
    GPIO15 Data        0x0 (0x0)
    GPIO16 Data        0x0 (0x0)
    GPIO17 Data        0x0 (0x0)
    GPIO18 Data        0x0 (0x0)
    GPIO19 Data        0x0 (0x0)
    GPIO20 Data        0x0 (0x0)
    GPIO21 Data        0x0 (0x0)
    GPIO0 Direction    0x1 (0x1)
    GPIO1 Direction    0x1 (0x1)
    GPIO2 Direction    0x1 (0x1)
    GPIO3 Direction    0x0 (0x0)
    GPIO4 Direction    0x0 (0x0)
    GPIO5 Direction    0x0 (0x0)
    GPIO6 Direction    0x0 (0x0)
    GPIO7 Direction    0x0 (0x0)
    GPIO8 Direction    0x0 (0x0)
    GPIO9 Direction    0x0 (0x0)
    GPIO10 Direction   0x0 (0x0)
    GPIO11 Direction   0x0 (0x0)
    GPIO12 Direction   0x0 (0x0)
    GPIO13 Direction   0x0 (0x0)
    GPIO14 Direction   0x1 (0x1)
    GPIO15 Direction   0x1 (0x1)
    GPIO16 Direction   0x0 (0x0)
    GPIO17 Direction   0x1 (0x1)
    GPIO18 Direction   0x0 (0x0)
    GPIO19 Direction   0x0 (0x0)
    GPIO20 Direction   0x1 (0x1)
    GPIO21 Direction   0x0 (0x0)

Received Alert Data Object (ADO) Register (0x74) - (0x0)
  Received Alert Data Object (ADO) Register
    Hot Swap Batteries   0x0 (0x0)
    Fixed Batteries      0x0 (0x0)
    Alert Type           0x0 (0x0)

Transmit Alert Data Object (ADO) Register (0x75) - (0x0)
  Transmit Alert Data Object (ADO) Register
    Hot Swap Batteries   0x0 (0x0)
    Fixed Batteries      0x0 (0x0)
    Alert Type           0x0 (0x0)

Received Source Capabilities Extended Data Block (SCEDB) Register (0x76) - (0x0)
  Received Source Capabilities Extended Data Block (SCEDB) Register
    VID                 0x0 (0x0)
    PID                 0x0 (0x0)
    PXD                 0x0 (0x0)
    FW Version          0x0 (0x0)
    HW Version          0x0 (0x0)
    VoltageRegulation   0x0 (0x0)
    Holdup Time         0x0 (0x0)
    Compliance          0x0 (0x0)
    TouchCurrent        0x0 (0x0)
    Peak Current 1      0x0 (0x0)
    Peak Current 2      0x0 (0x0)
    Peak Current 3      0x0 (0x0)
    Touch Temperature   0x0 (0x0)
    Source Inputs       0x0 (0x0)
    Batteries           0x0 (0x0)
    Source PD Power     0 W (0x0)

Received Status Data Block (SDB) Register (0x78) - (0x0)
  Received Status Data Block (SDB) Register
    Internal Temperature    0 (0x0)
    Present Input           0x0 (0x0)
    Present Battery Input   0x0 (0x0)
    Event Flags             0x0 (0x0)
    Temperature Status      0x0 (0x0)

Transmitted Status Data Block (SDB) Register (0x79) - (0x0)
  Transmitted Status Data Block (SDB) Register
    Internal Temperature    0 (0x0)
    Present Input           0x0 (0x0)
    Present Battery Input   0x0 (0x0)
    Event Flags             0x0 (0x0)
    Temperature Status      0x0 (0x0)

Received Battery Status Data Objects (BSDO) Register (0x7a) - (0x0)
  Received Battery Status Data Objects (BSDO) Register
    Battery Info                          0 (0x0)
    Battery State of Charge (SOC)         0x0 (0x0)
    Latest BSDO Fixed Battery 0           0x0 (0x0)
    Latest BSDO Fixed Battery 1           0x0 (0x0)
    Latest BSDO Fixed Battery 2           0x0 (0x0)
    Latest BSDO Fixed Battery 3           0x0 (0x0)
    Latest BSDO Hot-Swappable Battery 0   0x0 (0x0)
    Latest BSDO Hot-Swappable Battery 1   0x0 (0x0)
    Latest BSDO Hot-Swappable Battery 2   0x0 (0x0)
    Latest BSDO Hot-Swappable Battery 3   0x0 (0x0)

Transmitted Battery Status Data Objects (BSDO) Register (0x7b) - (0x0)
  Transmitted Battery Status Data Objects (BSDO) Register
    Battery Info                          0 (0x0)
    Battery State of Charge (SOC)         0x0 (0x0)
    Latest BSDO Fixed Battery 0           0x0 (0x0)
    Latest BSDO Fixed Battery 1           0x0 (0x0)
    Latest BSDO Fixed Battery 2           0x0 (0x0)
    Latest BSDO Fixed Battery 3           0x0 (0x0)
    Latest BSDO Hot-Swappable Battery 0   0x0 (0x0)
    Latest BSDO Hot-Swappable Battery 1   0x0 (0x0)
    Latest BSDO Hot-Swappable Battery 2   0x0 (0x0)
    Latest BSDO Hot-Swappable Battery 3   0x0 (0x0)

Received Battery Capability Data Block (BCDB) Register (0x7c) - (0x0)
  Received Battery Capability Data Block (BCDB) Register
    VID                                 0 (0x0)
    PID                                 0x0 (0x0)
    Battery Design Capacity             0 (0x0)
    Battery Last Full Charge Capacity   0 (0x0)
    Battery Type                        0 (0x0)

Received Manufacturer Info Data Block SOPp (MIDB) Register (0x7e) - (0x0)
  Received Manufacturer Info Data Block SOPp (MIDB) Register
    VID                   0 (0x0)
    PID                   0x0 (0x0)
    Manufacturer String   0 (0x0)